Foto | Herst. Teil # | Verfügbarkeit | Preis | Menge | Datenblatt | Packaging | Series | ProductStatus | Type | DisconnectType | NumberofPositions | NumberofLevels | Terminal-Width | TerminationStyle | Current-IEC | Voltage-IEC | Current-UL | Voltage-UL | WireGaugeorRange-AWG | WireGaugeorRange-mm² | Features | Color |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
17466.2FEED-THROUGH TERMINAL |
3,537 | - |
|
Datenblatt |
Box | ZST | Active | Feed Through | - | 6 | 2 | 30.6mm | Push In, Spring | 24 A | 500V | 20 A | 300V | 12-20 AWG | 0.5-4mm² | - | Beige | |
2669030000MULTI LEVEL INSTALLATION TERMINA |
2,336 | - |
|
Datenblatt |
Box | A | Active | Feed Through | - | 5 | 3; 1 Grounded | 5.1mm | Push In | 24 A | 250V | 20 A | 300V | 12-26 AWG | 0.5-4mm² | - | Beige | |
3210279CONN TERM BLK FEED THRU 12-26AWG |
3,066 | - |
|
Datenblatt |
Box | CLIPLINE PT | Active | Feed Through | - | 4 | 1 | 5.2mm | Push In, Spring | 0.5 A | 800V | 20 A | 300V | 12-26 AWG | 0.14-4mm² | Diode | Gray | |
2216-12042-CONDUCTOR THROUGH TERMINAL BLO |
2,324 | - |
|
Datenblatt |
Box | TOPJOB®S | Active | Feed Through | - | 2 | 1 | 12.0mm | Push In, Spring | 90 A | 800V | 85 A | 600V | 6-20 AWG | 0.5-16mm² | - | Blue | |
0354560000CONN TERM BLK GROUND 10-22AWG |
2,420 | - |
|
Datenblatt |
Bulk | SAK | Active | Ground, Earth | - | 2 | 1 | 8.0mm | Screw | - | - | - | - | 10-22 AWG | 0.5-6mm² | - | Green, Yellow | |
3606.5DISCONNECT TERMINAL |
3,128 | - |
|
Datenblatt |
Box | ZTRK | Active | Disconnect | - | 2 | 1 | 5.1mm | Push In, Spring | 18 A | 400V | - | - | 12-20 AWG | 0.5-4mm² | Diode | Blue | |
CPDLG1.5DIN TERM BLK, PUSH-IN, DBL LEVEL |
2,382 | - |
|
Datenblatt |
Box | CP | Active | Feed Through | - | 4 | 2; 1 Grounded | 3.5mm | Push In, Spring | 16 A | 500V | 15 A | 300V | 14-24 AWG | 0.2-1.5mm² | - | Gray | |
ATX25CONN TERM BLK FEED THRU 2-14 AWG |
2,526 | - |
|
Tray | ATX | Active | Feed Through | - | 2 | 1 | 12.0mm | Screw | 101 A | 800V | 115 A | 600V | 2-14 AWG | 6-25mm² | Explosion Proof, Harsh Environment | Gray | ||
ATX25BGCONN TERM BLK FEED THRU 2-14 AWG |
3,485 | - |
|
Tray | ATX | Active | Feed Through | - | 2 | 1 | 12.0mm | Screw | 101 A | 800V | 115 A | 600V | 2-14 AWG | 6-25mm² | Explosion Proof, Harsh Environment | Beige | ||
ATX25BKCONN TERM BLK FEED THRU 2-14 AWG |
3,845 | - |
|
Tray | ATX | Active | Feed Through | - | 2 | 1 | 12.0mm | Screw | 101 A | 800V | 115 A | 600V | 2-14 AWG | 6-25mm² | Explosion Proof, Harsh Environment | Black | ||
ATX25BRCONN TERM BLK FEED THRU 2-14 AWG |
2,770 | - |
|
Tray | ATX | Active | Feed Through | - | 2 | 1 | 12.0mm | Screw | 101 A | 800V | 115 A | 600V | 2-14 AWG | 6-25mm² | Explosion Proof, Harsh Environment | Brown | ||
ATX25BUCONN TERM BLK FEED THRU 2-14 AWG |
2,317 | - |
|
Tray | ATX | Active | Feed Through | - | 2 | 1 | 12.0mm | Screw | 101 A | 800V | 115 A | 600V | 2-14 AWG | 6-25mm² | Explosion Proof, Harsh Environment | Blue | ||
ATX25FCONN TERM BLK FEED THRU 2-14 AWG |
3,273 | - |
|
Tray | ATX | Active | Feed Through | - | 2 | 1 | 12.0mm | Screw | 101 A | 800V | 115 A | 600V | 2-14 AWG | 6-25mm² | Explosion Proof, Harsh Environment | Orange | ||
ATX25GCONN TERM BLK FEED THRU 2-14 AWG |
3,416 | - |
|
Tray | ATX | Active | Feed Through | - | 2 | 1 | 12.0mm | Screw | 101 A | 800V | 115 A | 600V | 2-14 AWG | 6-25mm² | Explosion Proof, Harsh Environment | Green | ||
ATX25RCONN TERM BLK FEED THRU 2-14AWG |
3,259 | - |
|
Tray | ATX | Active | Feed Through | - | 2 | 1 | 12.0mm | Screw | 101 A | 800V | 115 A | 600V | 2-14 AWG | 6-25mm² | Explosion Proof, Harsh Environment | Red | ||
ATX25WCONN TERM BLK FEED THRU 2-14 AWG |
2,046 | - |
|
Tray | ATX | Active | Feed Through | - | 2 | 1 | 12.0mm | Screw | 101 A | 800V | 115 A | 600V | 2-14 AWG | 6-25mm² | Explosion Proof, Harsh Environment | White | ||
ATX25YCONN TERM BLK FEED THRU 2-14 AWG |
2,454 | - |
|
Tray | ATX | Active | Feed Through | - | 2 | 1 | 12.0mm | Screw | 101 A | 800V | 115 A | 600V | 2-14 AWG | 6-25mm² | Explosion Proof, Harsh Environment | Yellow | ||
DDFL4U(E)LR/110FUSETERMDBL LVL BRIDGED WLED 63A |
2,134 | - |
|
Bulk | * | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
DDFL4U(E)LR/24FUSETERMDBL LVL BRIDGED WLED 63A |
3,305 | - |
|
Bulk | * | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
DDFL4U(E)LR/48FUSETERMDBL LVL BRIDGED WLED 63A |
2,123 | - |
|
Bulk | * | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - |