Foto | Herst. Teil # | Verfügbarkeit | Preis | Menge | Datenblatt | Packaging | Series | ProductStatus | Function | Voltage-Supply | TripRange | DelayTime | MountingType | TerminationStyle | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
VR-1-H-1VOLTAGE PROTECTION RELAY 1-PHASE |
3,297 | - |
|
Datenblatt |
Bulk | - | Active | Ground Fault, Overvoltage, Phase Imbalance, Phase Loss, Phase Sequence, Undervoltage | 220 ~ 254VAC | 165 ~ 317.5VAC | 0 ~ 10s | DIN Rail | Screw Terminal | - | |
VR-3-H-1VOLTAGE PROTECTION RELAY 3-PHASE |
2,587 | - |
|
Datenblatt |
Bulk | - | Active | Ground Fault, Overvoltage, Phase Imbalance, Phase Loss, Phase Sequence, Undervoltage | 415 ~ 480VAC | 311.25 ~ 600VAC | 0 ~ 10s | DIN Rail | Screw Terminal | - | |
VR-3-L-1VOLTAGE PROTECTION RELAY 3-PHASE |
3,046 | - |
|
Datenblatt |
Bulk | - | Active | Ground Fault, Overvoltage, Phase Imbalance, Phase Loss, Phase Sequence, Undervoltage | 110 ~ 240VAC | 82.5 ~ 300VAC | 0 ~ 10s | DIN Rail | Screw Terminal | - | |
VR-3-M-1VOLTAGE PROTECTION RELAY 3-PHASE |
3,466 | - |
|
Datenblatt |
Bulk | - | Active | Ground Fault, Overvoltage, Phase Imbalance, Phase Loss, Phase Sequence, Undervoltage | 381 ~ 415VAC | 518.75 ~ 285.75VAC | 0 ~ 10s | DIN Rail | Screw Terminal | - | |
VR-1-L-2VOLTAGE PROTECTION RELAY 1-PHASE |
2,191 | - |
|
Datenblatt |
Bulk | - | Active | Ground Fault, Overvoltage, Phase Imbalance, Phase Loss, Phase Sequence, Undervoltage | 58 ~ 138VAC | 43.5 ~ 172.5VAC | 0 ~ 10s | DIN Rail | Screw Terminal | - | |
VR-1-H-2VOLTAGE PROTECTION RELAY 1-PHASE |
2,558 | - |
|
Datenblatt |
Bulk | - | Active | Ground Fault, Overvoltage, Phase Imbalance, Phase Loss, Phase Sequence, Undervoltage | 220 ~ 254VAC | 165 ~ 317.5VAC | 0 ~ 10s | DIN Rail | Screw Terminal | - | |
VR-3-L-2VOLTAGE PROTECTION RELAY 3-PHASE |
2,219 | - |
|
Datenblatt |
Bulk | - | Active | Ground Fault, Overvoltage, Phase Imbalance, Phase Loss, Phase Sequence, Undervoltage | 110 ~ 240VAC | 82.5 ~ 300VAC | 0 ~ 10s | DIN Rail | Screw Terminal | - | |
VR-3-H-2VOLTAGE PROTECTION RELAY 3-PHASE |
3,420 | - |
|
Datenblatt |
Bulk | - | Active | Ground Fault, Overvoltage, Phase Imbalance, Phase Loss, Phase Sequence, Undervoltage | 415 ~ 480VAC | 311.25 ~ 600VAC | 0 ~ 10s | DIN Rail | Screw Terminal | - | |
VR-3-M-2VOLTAGE PROTECTION RELAY 3-PHASE |
2,444 | - |
|
Datenblatt |
Bulk | - | Active | Ground Fault, Overvoltage, Phase Imbalance, Phase Loss, Phase Sequence, Undervoltage | 381 ~ 415VAC | 518.75 ~ 285.75VAC | 0 ~ 10s | DIN Rail | Screw Terminal | - | |
AR-1-1-2CURRENT PROTECTION RELAY 1-PHASE |
3,960 | - |
|
Datenblatt |
Bulk | AR | Active | Ground Fault, Overcurrent, Undercurrent | 60 ~ 300VAC/DC | 1 ~ 5A | 0 ~ 10s | DIN Rail | Screw Terminal | Automatic Reset, Manual Reset | |
AR-1-1-1CURRENT PROTECTION RELAY 1-PHASE |
2,469 | - |
|
Datenblatt |
Bulk | AR | Active | Ground Fault, Overcurrent, Undercurrent | 60 ~ 300VAC/DC | 1 ~ 5A | 0 ~ 10s | DIN Rail | Screw Terminal | Automatic Reset, Manual Reset | |
AR-1-2-1CURRENT PROTECTION RELAY 1-PHASE |
2,464 | - |
|
Datenblatt |
Bulk | AR | Active | Ground Fault, Overcurrent, Undercurrent | 60 ~ 300VAC/DC | 1 ~ 5A | 0 ~ 10s | DIN Rail | Screw Terminal | Automatic Reset, Manual Reset | |
AR-3-1-2CURRENT PROTECTION RELAY 3-PHASE |
2,912 | - |
|
Datenblatt |
Bulk | AR | Active | Ground Fault, Overcurrent, Undercurrent | 60 ~ 300VAC/DC | 1 ~ 5A | 0 ~ 10s | DIN Rail | Screw Terminal | Automatic Reset, Manual Reset | |
AR-1-2-2CURRENT PROTECTION RELAY 1-PHASE |
3,169 | - |
|
Datenblatt |
Bulk | AR | Active | Ground Fault, Overcurrent, Undercurrent | 60 ~ 300VAC/DC | 1 ~ 5A | 0 ~ 10s | DIN Rail | Screw Terminal | Automatic Reset, Manual Reset | |
AR-3-1-1CURRENT PROTECTION RELAY 3-PHASE |
3,109 | - |
|
Datenblatt |
Bulk | AR | Active | Ground Fault, Overcurrent, Undercurrent | 60 ~ 300VAC/DC | 1 ~ 5A | 0 ~ 10s | DIN Rail | Screw Terminal | Automatic Reset, Manual Reset | |
AR-3-2-2CURRENT PROTECTION RELAY 3-PHASE |
2,039 | - |
|
Datenblatt |
Bulk | AR | Active | Ground Fault, Overcurrent, Undercurrent | 60 ~ 300VAC/DC | 1 ~ 5A | 0 ~ 10s | DIN Rail | Screw Terminal | Automatic Reset, Manual Reset | |
AR-3-2-1CURRENT PROTECTION RELAY 3-PHASE |
2,866 | - |
|
Datenblatt |
Bulk | AR | Active | Ground Fault, Overcurrent, Undercurrent | 60 ~ 300VAC/DC | 1 ~ 5A | 0 ~ 10s | DIN Rail | Screw Terminal | Automatic Reset, Manual Reset | |
RISH RELAY V/HZ-3-1002-LALINE MONITORING RELAY 3-PHASE |
2,214 | - |
|
Datenblatt |
Bulk | - | Active | Overfrequency, Overvoltage, Phase Imbalance, Phase Loss, Underfrequency, Undervoltage | 20 ~ 40VAC, 60VDC | 45Hz ~ 66Hz | 0 ~ 30s | DIN Rail | Screw Terminal | Automatic Reset, Manual Reset, Test Button | |
RISH RELAY V-3-3000-LAVOLTAGE PROTECTION RELAY 3-PHASE |
2,473 | - |
|
Datenblatt |
Bulk | RISH Relay-V | Active | Overvoltage, Phase Imbalance, Phase Loss, Undervoltage | 20 ~ 40VAC, 60VDC | - | 0 ~ 30s | DIN Rail | Screw Terminal | Automatic Reset, Manual Reset, Test Button | |
RISH RELAY V/HZ-3-1000-LALINE MONITORING RELAY 3-PHASE |
3,723 | - |
|
Datenblatt |
Bulk | - | Active | Overfrequency, Overvoltage, Phase Imbalance, Phase Loss, Underfrequency, Undervoltage | 20 ~ 40VAC, 60VDC | 45Hz ~ 66Hz | 0 ~ 30s | DIN Rail | Screw Terminal | Automatic Reset, Manual Reset, Test Button |