Foto | Herst. Teil # | Verfügbarkeit | Preis | Menge | Datenblatt | Packaging | Series | ProductStatus | OutputIsolation | InternalSwitch(s) | Voltage-Breakdown | Topology | Voltage-StartUp | Voltage-Supply(Vcc/Vdd) | DutyCycle | Frequency-Switching | Power(Watts) | FaultProtection | ControlFeatures | OperatingTemperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ICE3B5065IIC OFFLINE SWITCH FLYBACK TO220 |
2,912 | - |
|
Datenblatt |
Tube | CoolMOS™, CoolSET™F3 | Discontinued at Mosen | Isolated | Yes | 650V | Flyback | 15 V | 8.5V ~ 21V | 72% | 67kHz | 220 W | Current Limiting, Open Loop, Over Load, Over Temperature, Over Voltage | Soft Start | -25°C ~ 130°C (TJ) | |
ICE3B5065PBKSA1IC OFFLINE SW FLYBACK TO220-6 |
3,037 | - |
|
Datenblatt |
Tube,Tube | CoolMOS™, CoolSET™F3 | Obsolete | Isolated | Yes | 650V | Flyback | 15 V | 8.5V ~ 21V | 72% | 67kHz | 220 W | Current Limiting, Open Loop, Over Load, Over Temperature, Over Voltage | Soft Start | -25°C ~ 130°C (TJ) | |
ICE3B5565IIC OFFLINE SWITCH FLYBACK TO220 |
2,449 | - |
|
Datenblatt |
Tube | CoolMOS™, CoolSET™F3 | Discontinued at Mosen | Isolated | Yes | 650V | Flyback | 15 V | 8.5V ~ 21V | 72% | 67kHz | 240 W | Current Limiting, Open Loop, Over Load, Over Temperature, Over Voltage | Soft Start | -25°C ~ 130°C (TJ) | |
ICE3B5565PBKSA1IC OFFLINE SW FLYBACK TO220-6 |
3,632 | - |
|
Datenblatt |
Tube,Tube | CoolMOS™, CoolSET™F3 | Obsolete | Isolated | Yes | 650V | Flyback | 15 V | 8.5V ~ 21V | 72% | 67kHz | 240 W | Current Limiting, Open Loop, Over Load, Over Temperature, Over Voltage | Soft Start | -25°C ~ 130°C (TJ) | |
ICE3BS02IC OFFLINE SWITCH FLYBACK 8DIP |
3,137 | - |
|
Datenblatt |
Tube,Tube | CoolSET®F3 | Obsolete | Isolated | No | - | Flyback | 15 V | 8.5V ~ 21V | 72% | 67kHz | - | Current Limiting, Open Loop, Over Load, Over Temperature, Over Voltage | Soft Start | -25°C ~ 130°C (TJ) | |
ICE3BS02GIC OFFLINE SWITCH FLYBACK 8DSO |
2,958 | - |
|
Datenblatt |
Tape & Reel (TR),Bulk | CoolSET®F3 | Obsolete | Isolated | No | - | Flyback | 15 V | 8.5V ~ 21V | 72% | 67kHz | - | Current Limiting, Open Loop, Over Load, Over Temperature, Over Voltage | Soft Start | -25°C ~ 130°C (TJ) | |
ICE3BS02LIC OFFLINE SWITCH FLYBACK 8DIP |
2,335 | - |
|
Datenblatt |
Tube | CoolSET®F3 | Discontinued at Mosen | Isolated | No | - | Flyback | 15 V | 8.5V ~ 20V | 72% | 67kHz | - | Current Limiting, Open Loop, Over Load, Over Temperature, Over Voltage | Soft Start | -25°C ~ 130°C (TJ) | |
ICE3DS01LIC OFFLINE SWITCH FLYBACK 8DIP |
2,265 | - |
|
Datenblatt |
Tube | CoolSET®F3 | Obsolete | Isolated | No | - | Flyback | 15 V | 8.5V ~ 20V | 72% | 110kHz | - | Current Limiting, Open Loop, Over Load, Over Temperature, Over Voltage | Soft Start | -25°C ~ 130°C (TJ) | |
ICE3DS01LGIC OFFLINE SWITCH FLYBACK 8DSO |
2,320 | - |
|
Datenblatt |
Tape & Reel (TR) | CoolSET®F3 | Obsolete | Isolated | No | - | Flyback | 15 V | 8.5V ~ 20V | 72% | 110kHz | - | Current Limiting, Open Loop, Over Load, Over Temperature, Over Voltage | Soft Start | -25°C ~ 130°C (TJ) | |
TDA16822XKIC OFFLINE SWITCH FLYBACK 8DIP |
2,806 | - |
|
Datenblatt |
Tube | CoolSET®F1 | Discontinued at Mosen | Isolated | Yes | 650V | Flyback | 14 V | 9V ~ 17V | 72% | 100kHz | 20 W | Current Limiting, Open Loop, Over Load, Over Temperature, Over Voltage | Soft Start | -25°C ~ 130°C (TJ) | |
FSQ311IC OFFLINE SWITCH FLYBACK 8DIP |
3,068 | - |
|
Datenblatt |
Tube | - | Obsolete | Isolated | Yes | 650V | Flyback | 12 V | 8V ~ 20V | - | - | 12 W | Current Limiting, Over Load, Over Temperature, Over Voltage | Sync | -40°C ~ 85°C (TA) | |
PKS603PNIC OFFLINE SWITCH FLYBACK 8DIP |
2,924 | - |
|
Datenblatt |
Tube | PeakSwitch® | Obsolete | Isolated | Yes | 700V | Flyback | - | - | 65% | 277kHz | 32 W | Current Limiting, Over Load, Over Temperature | EN | -40°C ~ 150°C (TJ) | |
PKS604PNIC OFFLINE SWITCH FLYBACK 8DIP |
3,417 | - |
|
Datenblatt |
Tube | PeakSwitch® | Obsolete | Isolated | Yes | 700V | Flyback | - | - | 65% | 277kHz | 56 W | Current Limiting, Over Load, Over Temperature | EN | -40°C ~ 150°C (TJ) | |
PKS605PNIC OFFLINE SWITCH FLYBACK 8DIP |
2,311 | - |
|
Datenblatt |
Tube | PeakSwitch® | Obsolete | Isolated | Yes | 700V | Flyback | - | - | 65% | 277kHz | 60 W | Current Limiting, Over Load, Over Temperature | EN | -40°C ~ 150°C (TJ) | |
PKS606PNIC OFFLINE SWITCH FLYBACK 8DIP |
3,304 | - |
|
Datenblatt |
Tube | PeakSwitch® | Obsolete | Isolated | Yes | 700V | Flyback | - | - | 65% | 277kHz | 66 W | Current Limiting, Over Load, Over Temperature | EN | -40°C ~ 150°C (TJ) | |
PKS604YNIC OFFLINE SW FLYBACK TO220-7C |
3,589 | - |
|
Datenblatt |
Tube | PeakSwitch® | Obsolete | Isolated | Yes | 700V | Flyback | - | - | 65% | 277kHz | 56 W | Current Limiting, Over Load, Over Temperature | EN | -40°C ~ 150°C (TJ) | |
PKS605YNIC OFFLINE SW FLYBACK TO220-7C |
2,032 | - |
|
Datenblatt |
Tube | PeakSwitch® | Obsolete | Isolated | Yes | 700V | Flyback | - | - | 65% | 277kHz | 79 W | Current Limiting, Over Load, Over Temperature | EN | -40°C ~ 150°C (TJ) | |
PKS606YNIC OFFLINE SW FLYBACK TO220-7C |
3,394 | - |
|
Datenblatt |
Tube | PeakSwitch® | Obsolete | Isolated | Yes | 700V | Flyback | - | - | 65% | 277kHz | 117 W | Current Limiting, Over Load, Over Temperature | EN | -40°C ~ 150°C (TJ) | |
PKS604FNIC OFFLINE SW FLYBACK TO262-7C |
2,872 | - |
|
Datenblatt |
Tube | PeakSwitch® | Obsolete | Isolated | Yes | 700V | Flyback | - | - | 65% | 277kHz | 56 W | Current Limiting, Over Load, Over Temperature | EN | -40°C ~ 150°C (TJ) | |
PKS605FNIC OFFLINE SW FLYBACK TO262-7C |
2,178 | - |
|
Datenblatt |
Tube | PeakSwitch® | Obsolete | Isolated | Yes | 700V | Flyback | - | - | 65% | 277kHz | 79 W | Current Limiting, Over Load, Over Temperature | EN | -40°C ~ 150°C (TJ) |