Foto | Herst. Teil # | Verfügbarkeit | Preis | Menge | Datenblatt | Packaging | Series | ProductStatus | Voltage-Rated | Size/Dimension | Width | AirFlow | StaticPressure | BearingType | FanType | Features | Noise | Power(Watts) | RPM | Termination | IngressProtection | OperatingTemperature | ApprovalAgency |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
109L1424H102FAN 140X38MM 24VDC RBLS |
3,993 | - |
|
Datasheet |
Box | San Ace 140L | Obsolete | 24VDC | Square - 140mm L x 140mm H | 38.00mm | 159.0 CFM (4.45m³/min) | 0.394 in H2O (98.1 Pa) | Ball | Tubeaxial | Locked Rotor Protection | 46.0dB(A) | 8.88 W | 2600 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | |
109L1424H1D01FAN 140X38MM 24VDC RBLS LOCK |
2,801 | - |
|
Datasheet |
Box | San Ace 140L | Obsolete | 24VDC | Square - 140mm L x 140mm H | 38.00mm | 159.0 CFM (4.45m³/min) | 0.394 in H2O (98.1 Pa) | Ball | Tubeaxial | Locked Rotor Sensor | 46.0dB(A) | 8.88 W | 2600 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | |
109L1424M101FAN 140X38MM 24VDC RBLS TACH |
2,024 | - |
|
Datasheet |
Box | San Ace 140L | Obsolete | 24VDC | Square - 140mm L x 140mm H | 38.00mm | 117.0 CFM (3.28m³/min) | 0.209 in H2O (52.1 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 38.0dB(A) | 3.84 W | 1900 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | |
109P0512T7H122FAN 52X15MM 12VDC THERM |
3,721 | - |
|
Datasheet |
Box | San Ace 52 | Obsolete | 12VDC | Square - 52mm L x 52mm H | 15.00mm | 9.5 CFM (0.266m³/min) | 0.145 in H2O (36.1 Pa) | Ball | Tubeaxial | Thermistor | 28.0dB(A) | 1.56 W | 4900 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CSA, TUV, UL | |
109P0612T6H12FAN 60X20MM 12VDC THERM |
2,530 | - |
|
Datasheet |
Box | San Ace 60 | Obsolete | 12VDC | Square - 60mm L x 60mm H | 20.00mm | 14.8 CFM (0.414m³/min) | 0.128 in H2O (31.9 Pa) | Ball | Tubeaxial | Thermistor, External | 31.0dB(A) | 1.8 W | 4400 RPM | 3 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CSA, TUV, UL | |
109P0612T7H112FAN 60X15MM 12VDC TACH THERM |
3,488 | - |
|
Datasheet |
Box | San Ace 60 | Obsolete | 12VDC | Square - 60mm L x 60mm H | 15.00mm | - | - | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 32.0dB(A) | 1.44 W | 4330 RPM | 3 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CSA, TUV, UL | |
109P0612T7H12FAN 60X15MM 12VDC THERM |
3,852 | - |
|
Datasheet |
Box | San Ace 60 | Obsolete | 12VDC | Square - 60mm L x 60mm H | 15.00mm | 14.1 CFM (0.395m³/min) | 0.153 in H2O (38.2 Pa) | Ball | Tubeaxial | Thermistor, External | 32.0dB(A) | 1.44 W | 4100 RPM | 3 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CSA, TUV, UL | |
109P0612T7H122FAN 60X15MM 12VDC THERM |
2,793 | - |
|
Datasheet |
Box | San Ace 60 | Obsolete | 12VDC | Square - 60mm L x 60mm H | 15.00mm | 14.8 CFM (0.414m³/min) | 0.169 in H2O (42.1 Pa) | Ball | Tubeaxial | Thermistor | 32.0dB(A) | 1.44 W | 4300 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CSA, TUV, UL | |
109P0812A2011FAN 80X32MM 12VDC RBLS TACH |
2,411 | - |
|
Datasheet |
Box | San Ace 80 | Obsolete | 12VDC | Square - 80mm L x 80mm H | 32.00mm | 53.7 CFM (1.50m³/min) | 0.366 in H2O (91.2 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 45.0dB(A) | 6.72 W | 4600 RPM | 3 Wire Leads | - | -4 ~ 131°F (-20 ~ 55°C) | CSA, TUV, UL | |
109P0812A202FAN 80X32MM 12VDC |
3,675 | - |
|
Datasheet |
Box | San Ace 80 | Obsolete | 12VDC | Square - 80mm L x 80mm H | 32.00mm | 53.7 CFM (1.50m³/min) | 0.366 in H2O (91.2 Pa) | Ball | Tubeaxial | Locked Rotor Protection | 45.0dB(A) | 6.72 W | 4600 RPM | 2 Wire Leads | - | -4 ~ 131°F (-20 ~ 55°C) | CSA, TUV, UL | |
109P0812A2021FAN 80X32MM 12VDC RBLS |
3,141 | - |
|
Datasheet |
Box | San Ace 80 | Obsolete | 12VDC | Square - 80mm L x 80mm H | 32.00mm | 53.7 CFM (1.50m³/min) | 0.366 in H2O (91.2 Pa) | Ball | Tubeaxial | Locked Rotor Protection | 45.0dB(A) | 6.72 W | 4600 RPM | 2 Wire Leads | - | -4 ~ 131°F (-20 ~ 55°C) | CSA, TUV, UL | |
109P0812H201FAN 80X32MM 12VDC TACH |
2,680 | - |
|
Datasheet |
Box | San Ace 80 | Obsolete | 12VDC | Square - 80mm L x 80mm H | 32.00mm | 37.1 CFM (1.04m³/min) | 0.173 in H2O (43.1 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 33.0dB(A) | 1.92 W | 3150 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | |
109P0812H202FAN 80X32MM 12VDC |
3,978 | - |
|
Datasheet |
Box | San Ace 80 | Obsolete | 12VDC | Square - 80mm L x 80mm H | 32.00mm | 37.1 CFM (1.04m³/min) | 0.173 in H2O (43.1 Pa) | Ball | Tubeaxial | Locked Rotor Protection | 33.0dB(A) | 1.92 W | 3150 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | |
109P0812H2D01FAN 80X32MM 12VDC LOCK |
3,848 | - |
|
Datasheet |
Box | San Ace 80 | Obsolete | 12VDC | Square - 80mm L x 80mm H | 32.00mm | 37.1 CFM (1.04m³/min) | 0.173 in H2O (43.1 Pa) | Ball | Tubeaxial | Locked Rotor Sensor | 33.0dB(A) | 1.92 W | 3150 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | |
109P0812H2D011FAN 80X32MM 12VDC RBLS LOCK |
3,307 | - |
|
Datasheet |
Box | San Ace 80 | Obsolete | 12VDC | Square - 80mm L x 80mm H | 32.00mm | 37.1 CFM (1.04m³/min) | 0.173 in H2O (43.1 Pa) | Ball | Tubeaxial | Locked Rotor Sensor | 33.0dB(A) | 1.92 W | 3150 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | |
109P0812H7D01FAN 80X15MM 12VDC LOCK |
2,992 | - |
|
Datasheet |
Box | San Ace 80 | Obsolete | 12VDC | Square - 80mm L x 80mm H | 15.00mm | 32.1 CFM (0.899m³/min) | 0.118 in H2O (29.4 Pa) | Ball | Tubeaxial | Locked Rotor Sensor | 31.0dB(A) | 2.4 W | 3100 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | |
109P0824A2021FAN 80X32MM 24VDC RBLS |
3,039 | - |
|
Datasheet |
Box | San Ace 80 | Obsolete | 24VDC | Square - 80mm L x 80mm H | 32.00mm | 53.7 CFM (1.50m³/min) | 0.366 in H2O (91.2 Pa) | Ball | Tubeaxial | Locked Rotor Protection | 45.0dB(A) | 6.96 W | 4600 RPM | 2 Wire Leads | - | -4 ~ 140°F (-20 ~ 60°C) | CSA, TUV, UL | |
109P0824H201FAN 80X32MM 24VDC TACH |
2,218 | - |
|
Datasheet |
Box | San Ace 80 | Obsolete | 24VDC | Square - 80mm L x 80mm H | 32.00mm | 37.1 CFM (1.04m³/min) | 0.173 in H2O (43.1 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 33.0dB(A) | 2.16 W | 3150 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | |
109P0824H2011FAN 80X32MM 24VDC RBLS TACH |
3,974 | - |
|
Datasheet |
Box | San Ace 80 | Obsolete | 24VDC | Square - 80mm L x 80mm H | 32.00mm | 37.1 CFM (1.04m³/min) | 0.173 in H2O (43.1 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 33.0dB(A) | 2.16 W | 3150 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | |
109P0824M202FAN 80X32MM 24VDC |
3,215 | - |
|
Datasheet |
Box | San Ace 80 | Obsolete | 24VDC | Square - 80mm L x 80mm H | 32.00mm | 23.0 CFM (0.644m³/min) | 0.075 in H2O (18.6 Pa) | Ball | Tubeaxial | Locked Rotor Protection | 21.0dB(A) | 960 mW | 2000 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL |