Foto | Herst. Teil # | Verfügbarkeit | Preis | Menge | Datenblatt | Packaging | Series | ProductStatus | ForMeasuring | SensorType | Current-Sensing | NumberofChannels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage-Supply | ResponseTime | Current-Supply(Max) | OperatingTemperature | Polarization | MountingType |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CR4211S-20SENSOR CURRENT XFMR 20A AC |
2,788 | - |
|
![]() Datenblatt |
Bulk | CR4200 | Active | AC | Transformer w/Conditioning | 20A | 1 | Ratiometric, 0 V ~ 10 V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 250ms | - | 0°C ~ 60°C | Bidirectional | DIN Rail, Panel |
![]() |
CR4211S-50SENSOR CURRENT XFMR 50A AC |
2,908 | - |
|
![]() Datenblatt |
Bulk | CR4200 | Active | AC | Transformer w/Conditioning | 50A | 1 | Ratiometric, 0 V ~ 10 V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 250ms | - | 0°C ~ 60°C | Bidirectional | DIN Rail, Panel |
![]() |
CR4211S-200SENSOR CURRENT XFMR 200A AC |
2,177 | - |
|
![]() Datenblatt |
Bulk | CR4200 | Active | AC | Transformer w/Conditioning | 200A | 1 | Ratiometric, 0 V ~ 10 V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 250ms | - | 0°C ~ 60°C | Bidirectional | DIN Rail, Panel |
![]() |
CR4211S-5SENSOR CURRENT XFMR 5A AC |
2,160 | - |
|
![]() Datenblatt |
Bulk | CR4200 | Active | AC | Transformer w/Conditioning | 5A | 1 | Ratiometric, 0 V ~ 10 V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 250ms | - | 0°C ~ 60°C | Bidirectional | DIN Rail, Panel |
![]() |
CR4211S-10SENSOR CURRENT XFMR 10A AC |
2,269 | - |
|
![]() Datenblatt |
Bulk | CR4200 | Active | AC | Transformer w/Conditioning | 10A | 1 | Ratiometric, 0 V ~ 10 V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 250ms | - | 0°C ~ 60°C | Bidirectional | DIN Rail, Panel |
![]() |
CTL0501FSENSOR CURRENT XFMR 10A, 20, 50A |
2,865 | - |
|
![]() Datenblatt |
Bulk | CTL | Active | AC | Transformer w/Conditioning | 10A, 20, 50A (Selectable) | 1 | Ratiometric, 0 V ~ 10 V | - | 50Hz ~ 60Hz | - | ±1% | Self Powered | 100ms | - | -20°C ~ 50°C | Bidirectional | Chassis Mount |
![]() |
MNS2-9-W2-CM-500ALTAAC CURRENT METER - 500 AMP |
3,516 | - |
|
![]() Datenblatt |
Bulk | - | Active | AC | Current Sensor | 500A | - | - | - | 50Hz ~ 100Hz | - | ±2% | 2V ~ 3.8V | - | 22.6mA | -40°C ~ 85°C | - | Chassis Mount |
![]() |
CTSS0000SENSOR CURRENT SWITCH 150A AC |
2,988 | - |
|
![]() Datenblatt |
Bulk | CTS | Active | AC | Current Switch | 150A | 1 | SSR | - | 6Hz ~ 100Hz | - | - | Self Powered | 120ms | 150mA | -50°C ~ 65°C | Bidirectional | Chassis Mount |
![]() |
CR4420S-0.5SENSOR CURRENT XFMR 0.5A AC |
2,390 | - |
|
![]() Datenblatt |
Bulk | CR4400 | Active | AC | Transformer w/Conditioning | 500mA | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 45mA | 0°C ~ 60°C | Bidirectional | DIN Rail, Panel |
![]() |
CR4420S-5SENSOR CURRENT XFMR 5A AC |
2,986 | - |
|
![]() Datenblatt |
Bulk | CR4400 | Active | AC | Transformer w/Conditioning | 5A | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 45mA | 0°C ~ 60°C | Bidirectional | DIN Rail, Panel |
|
CR4110S-0.5SENSOR CURRENT XFMR 0.5A AC |
3,761 | - |
|
![]() Datenblatt |
Bulk | CR4100 | Active | AC | Transformer w/Conditioning | 500mA | 1 | Ratiometric, 0 V ~ 5 V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 25mA | 0°C ~ 60°C | Bidirectional | DIN Rail, Panel |
![]() |
CR4260-0.5SENSOR CURRENT XFMR 0.5A AC |
3,848 | - |
|
![]() Datenblatt |
Bulk | CR4200 | Active | AC | Transformer w/Conditioning | 500mA | 2 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | - | 0°C ~ 60°C | Bidirectional | DIN Rail, Panel |
![]() |
CSNJ481SENSOR CURRENT HALL 600A AC/DC |
3,954 | - |
|
![]() Datenblatt |
Bulk | CSN | Active | AC/DC | Hall Effect, Closed Loop | 600A | 1 | Ratiometric, Current | - | - | - | ±0.5% | ±12V ~ 18V | 0.5µs | 14mA | -40°C ~ 85°C | Bidirectional | Through Hole |
![]() |
CSNK591SENSOR CURRENT HALL 1200A AC/DC |
2,227 | - |
|
![]() Datenblatt |
Bulk | CSN | Active | AC/DC | Hall Effect, Closed Loop | 1200A | 1 | Ratiometric, Current | - | - | - | ±0.5% | ±15V ~ 24V | 1µs | 22mA | -40°C ~ 85°C | Bidirectional | Through Hole |
![]() |
CR4470-10SENSOR CURRENT XFMR 10A AC |
3,275 | - |
|
![]() Datenblatt |
Bulk | CR4400 | Active | AC | Transformer w/Conditioning | 10A | 3 | Ratiometric, 0 V ~ 5 V | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 110mA | 0°C ~ 60°C | Bidirectional | DIN Rail, Panel |
![]() |
CR4470-15SENSOR CURRENT XFMR 15A AC |
3,691 | - |
|
![]() Datenblatt |
Bulk | CR4400 | Active | AC | Transformer w/Conditioning | 15A | 3 | Ratiometric, 0 V ~ 5 V | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 110mA | 0°C ~ 60°C | Bidirectional | DIN Rail, Panel |
![]() |
CR4470-5SENSOR CURRENT XFMR 5A AC |
2,631 | - |
|
![]() Datenblatt |
Bulk | CR4400 | Active | AC | Transformer w/Conditioning | 5A | 3 | Ratiometric, 0 V ~ 5 V | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 110mA | 0°C ~ 60°C | Bidirectional | DIN Rail, Panel |
![]() |
CR4470-25SENSOR CURRENT XFMR 25A AC |
2,084 | - |
|
![]() Datenblatt |
Bulk | CR4400 | Active | AC | Transformer w/Conditioning | 25A | 3 | Ratiometric, 0 V ~ 5 V | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 110mA | 0°C ~ 60°C | Bidirectional | DIN Rail, Panel |
![]() |
CR4470-30SENSOR CURRENT XFMR 30A AC |
2,525 | - |
|
![]() Datenblatt |
Bulk | CR4400 | Active | AC | Transformer w/Conditioning | 30A | 3 | Ratiometric, 0 V ~ 5 V | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 110mA | 0°C ~ 60°C | Bidirectional | DIN Rail, Panel |
![]() |
CR4470-20SENSOR CURRENT XFMR 20A AC |
2,372 | - |
|
![]() Datenblatt |
Bulk | CR4400 | Active | AC | Transformer w/Conditioning | 20A | 3 | Ratiometric, 0 V ~ 5 V | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 110mA | 0°C ~ 60°C | Bidirectional | DIN Rail, Panel |