Foto | Herst. Teil # | Verfügbarkeit | Preis | Menge | Datenblatt | Packaging | Series | ProductStatus | ForMeasuring | SensorType | Current-Sensing | NumberofChannels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage-Supply | ResponseTime | Current-Supply(Max) | OperatingTemperature | Polarization | MountingType |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CPCO-4000-77-RMSDC-AC CURRENT PROBE, CLAMP-ON, 4 |
2,239 | - |
|
Datenblatt |
Box | CPCO | Active | AC/DC | Open Loop | 4000A | 1 | Ratiometric, 0V ~ 3V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 1s | 47mA | -40°C ~ 100°C | Bidirectional | Panel Mount | |
CPCO-2000-77-RMSDC-AC CURRENT PROBE, CLAMP-ON, 2 |
3,338 | - |
|
Datenblatt |
Box | CPCO | Active | AC/DC | Open Loop | 2000A | 1 | Ratiometric, 0V ~ 3V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 1s | 47mA | -40°C ~ 100°C | Bidirectional | Panel Mount | |
CPCO-1000-77-RMSDC-AC CURRENT PROBE, CLAMP-ON, 1 |
3,899 | - |
|
Datenblatt |
Box | CPCO | Active | AC/DC | Open Loop | 1000A | 1 | Ratiometric, 0V ~ 3V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 1s | 47mA | -40°C ~ 100°C | Bidirectional | Panel Mount | |
CPCO-2000-77-BP10DC-AC CURRENT PROBE, CLAMP-ON, 2 |
2,543 | - |
|
Datenblatt |
Box | CPCO | Active | AC/DC | Open Loop | 2000A | 1 | Ratiometric, ±10V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 10µs | 47mA | -40°C ~ 100°C | Bidirectional | Panel Mount | |
CPCO-4000-77-SEDC-AC CURRENT PROBE, CLAMP-ON, 4 |
2,650 | - |
|
Datenblatt |
Box | CPCO | Active | AC/DC | Open Loop | 4000A | 1 | Ratiometric, 0V ~ 10V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 10µs | 47mA | -40°C ~ 100°C | Bidirectional | Panel Mount | |
CPCO-1000-77-BP5DC-AC CURRENT PROBE, CLAMP-ON, 1 |
3,138 | - |
|
Datenblatt |
Box | CPCO | Active | AC/DC | Open Loop | 1000A | 1 | Ratiometric, ±5V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 10µs | 47mA | -40°C ~ 100°C | Bidirectional | Panel Mount | |
CPCO-1000-77-BP10DC-AC CURRENT PROBE, CLAMP-ON, 1 |
2,858 | - |
|
Datenblatt |
Box | CPCO | Active | AC/DC | Open Loop | 1000A | 1 | Ratiometric, ±10V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 10µs | 47mA | -40°C ~ 100°C | Bidirectional | Panel Mount | |
CPCO-4000-77-MADC-AC CURRENT PROBE, CLAMP-ON, 4 |
2,007 | - |
|
Datenblatt |
Box | CPCO | Active | AC/DC | Open Loop | 4000A | 1 | Ratiometric, 4mA ~ 20mA | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 26V | 10µs | 47mA | -40°C ~ 100°C | Bidirectional | Panel Mount | |
CPCO-4000-77-BP5DC-AC CURRENT PROBE, CLAMP-ON, 4 |
2,473 | - |
|
Datenblatt |
Box | CPCO | Active | AC/DC | Open Loop | 4000A | 1 | Ratiometric, ±5V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 10µs | 47mA | -40°C ~ 100°C | Bidirectional | Panel Mount | |
CPCO-2000-77-BP5DC-AC CURRENT PROBE, CLAMP-ON, 2 |
2,520 | - |
|
Datenblatt |
Box | CPCO | Active | AC/DC | Open Loop | 2000A | 1 | Ratiometric, ±5V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 10µs | 47mA | -40°C ~ 100°C | Bidirectional | Panel Mount | |
CPCO-1000-77-SEDC-AC CURRENT PROBE, CLAMP-ON, 1 |
3,794 | - |
|
Datenblatt |
Box | CPCO | Active | AC/DC | Open Loop | 1000A | 1 | Ratiometric, 0V ~ 10V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 10µs | 47mA | -40°C ~ 100°C | Bidirectional | Panel Mount | |
CPCO-2000-77-SEDC-AC CURRENT PROBE, CLAMP-ON, 2 |
2,951 | - |
|
Datenblatt |
Box | CPCO | Active | AC/DC | Open Loop | 2000A | 1 | Ratiometric, 0V ~ 10V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 10µs | 47mA | -40°C ~ 100°C | Bidirectional | Panel Mount | |
CSS-O-A200-001/UCURRENT SENSOR |
2,000 | - |
|
Box | * | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
CTP-20-200-AVG-001SPLIT CORE LOOP POWERED CURRENT |
3,932 | - |
|
Box | * | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
CTS-20-250-VFD-001CURRENT SENSOR |
3,657 | - |
|
Box | * | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
ACC-AC60SENSOR AC CURRENT 60A FOR WIRELE |
2,746 | - |
|
Datenblatt |
Bulk | ACxx | Active | AC | Current Sensor | - | 1 | - | - | - | 0.02% | ±5% | - | 15s | - | 0°C ~ 50°C | - | - | |
ACC-DC200SENSOR DC CURRENT 200A FOR A150 |
2,957 | - |
|
Datenblatt |
Bulk | DCxxx | Active | DC | Current Sensor | - | 1 | - | - | - | 0.02% | ±5% | 12V | 15s | 20mA | 0°C ~ 50°C | - | - | |
37001CURRENT XDUCER 50A/4-20MA |
2,415 | - |
|
Datenblatt |
Retail Package | - | Active | AC | Current Transducer | 50A | 1 | Ratiometric, 4mA ~ 20mA | - | 60Hz | - | ±0.04% | 21.6V ~ 26.4V | - | - | -30°C ~ 65°C | Unidirectional | Chassis Mount | |
37004CURRENT XDUCER 150A/4-20MA |
3,374 | - |
|
Datenblatt |
Retail Package | - | Active | AC | Current Transducer | 150A | 1 | Ratiometric, 4mA ~ 20mA | - | 60Hz | - | ±0.04% | 21.6V ~ 26.4V | - | - | -30°C ~ 65°C | Unidirectional | Chassis Mount | |
ACC-A10SENSOR AC CURRENT 60A WIRELESS E |
3,964 | - |
|
Datenblatt |
Bulk | A10 | Active | AC | Current Sensor | - | 1 | Digital | 0.1mA/A | - | 0.02% | ±5% | - | 15s | - | 0°C ~ 50°C | - | - |