Foto | Herst. Teil # | Verfügbarkeit | Preis | Menge | Datenblatt | Package/Case | Packaging | Series | ProductStatus | Resistance | Tolerance | Power(Watts) | Composition | TemperatureCoefficient | OperatingTemperature | Features | CoatingHousingType | MountingFeature | Size/Dimension | Height-Seated(Max) | LeadStyle |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HSW600 100R JALUM HOUSE 600W 100 OHMS 5% |
3,800 | - |
|
Datasheet |
Axial, Box | Box | HSW | Active | 100 Ohms | ±5% | 600W | - | ±25ppm/°C | - | Pulse Withstanding | Aluminum | Flanges | 4.488 L x 2.835 W (114.00mm x 72.00mm) | 1.772 (45.00mm) | Wire Leads | |
HS250 R5 FRES CHAS MNT 0.5 OHM 1% 250W |
3,123 | - |
|
Datasheet |
Axial, Box | Bulk | ARCOL, HS | Active | 500 mOhms | ±1% | 250W | Wirewound | ±100ppm/°C | - | - | Aluminum | Flanges | 4.319 L x 1.791 W (109.70mm x 45.50mm) | 1.646 (41.80mm) | M6 Threaded | |
NHS200 5R6 JALUM HOUSE 200W 5.6 OHMS 5% |
3,883 | - |
|
Datasheet |
Axial, Box | Box | ARCOL, HS | Active | 5.6 Ohms | ±5% | 200W | Wirewound | ±100ppm/°C | - | Non-Inductive, Pulse Withstanding | Aluminum | Flanges | 3.531 L x 2.854 W (89.70mm x 72.50mm) | 1.646 (41.80mm) | Solder Lugs | |
NHS200 2R FALUM HOUSE 200W 2 OHMS 1% |
2,275 | - |
|
Datasheet |
Axial, Box | Box | ARCOL, HS | Active | 2 Ohms | ±1% | 200W | Wirewound | ±100ppm/°C | - | Non-Inductive, Pulse Withstanding | Aluminum | Flanges | 3.531 L x 2.854 W (89.70mm x 72.50mm) | 1.646 (41.80mm) | Solder Lugs | |
NHS200 128R FALUM HOUSE 200W 128 OHMS 1% |
3,727 | - |
|
Datasheet |
Axial, Box | Box | ARCOL, HS | Active | 128 Ohms | ±1% | 200W | Wirewound | ±100ppm/°C | - | Non-Inductive, Pulse Withstanding | Aluminum | Flanges | 3.531 L x 2.854 W (89.70mm x 72.50mm) | 1.646 (41.80mm) | Solder Lugs | |
NHS200 220R FALUM HOUSE 200W 220 OHMS 1% |
3,808 | - |
|
Datasheet |
Axial, Box | Box | ARCOL, HS | Active | 220 Ohms | ±1% | 200W | Wirewound | ±100ppm/°C | - | Non-Inductive, Pulse Withstanding | Aluminum | Flanges | 3.531 L x 2.854 W (89.70mm x 72.50mm) | 1.646 (41.80mm) | Solder Lugs | |
NHS200 8R FALUM HOUSE 200W 8 OHMS 1% |
3,861 | - |
|
Datasheet |
Axial, Box | Box | ARCOL, HS | Active | 8 Ohms | ±1% | 200W | Wirewound | ±100ppm/°C | - | Non-Inductive, Pulse Withstanding | Aluminum | Flanges | 3.531 L x 2.854 W (89.70mm x 72.50mm) | 1.646 (41.80mm) | Solder Lugs | |
NHS200 5R6 FALUM HOUSE 200W 5.6 OHMS 1% |
3,878 | - |
|
Datasheet |
Axial, Box | Box | ARCOL, HS | Active | 5.6 Ohms | ±1% | 200W | Wirewound | ±100ppm/°C | - | Non-Inductive, Pulse Withstanding | Aluminum | Flanges | 3.531 L x 2.854 W (89.70mm x 72.50mm) | 1.646 (41.80mm) | Solder Lugs | |
NHS200 100R JALUM HOUSE 200W 100 OHMS 5% |
3,809 | - |
|
Datasheet |
Axial, Box | Box | ARCOL, HS | Active | 100 Ohms | ±5% | 200W | Wirewound | ±100ppm/°C | - | Non-Inductive, Pulse Withstanding | Aluminum | Flanges | 3.531 L x 2.854 W (89.70mm x 72.50mm) | 1.646 (41.80mm) | Solder Lugs | |
NHS200 2R2 FALUM HOUSE 200W 2.2 OHMS 1% |
3,411 | - |
|
Datasheet |
Axial, Box | Box | ARCOL, HS | Active | 2.2 Ohms | ±1% | 200W | Wirewound | ±100ppm/°C | - | Non-Inductive, Pulse Withstanding | Aluminum | Flanges | 3.531 L x 2.854 W (89.70mm x 72.50mm) | 1.646 (41.80mm) | Solder Lugs | |
NHS200 22R JALUM HOUSE 200W 22 OHMS 5% |
3,630 | - |
|
Datasheet |
Axial, Box | Box | ARCOL, HS | Active | 22 Ohms | ±5% | 200W | Wirewound | ±100ppm/°C | - | Non-Inductive, Pulse Withstanding | Aluminum | Flanges | 3.531 L x 2.854 W (89.70mm x 72.50mm) | 1.646 (41.80mm) | Solder Lugs | |
NHS200 68R JALUM HOUSE 200W 68 OHMS 5% |
3,914 | - |
|
Datasheet |
Axial, Box | Box | ARCOL, HS | Active | 68 Ohms | ±5% | 200W | Wirewound | ±100ppm/°C | - | Non-Inductive, Pulse Withstanding | Aluminum | Flanges | 3.531 L x 2.854 W (89.70mm x 72.50mm) | 1.646 (41.80mm) | Solder Lugs | |
NHS200 1K JALUM HOUSE 200W 1K OHMS 5% |
2,682 | - |
|
Datasheet |
Axial, Box | Box | ARCOL, HS | Active | 1 kOhms | ±5% | 200W | Wirewound | ±25ppm/°C | - | Non-Inductive, Pulse Withstanding | Aluminum | Flanges | 3.531 L x 2.854 W (89.70mm x 72.50mm) | 1.646 (41.80mm) | Solder Lugs | |
NHS200 47R JALUM HOUSE 200W 47 OHMS 5% |
3,669 | - |
|
Datasheet |
Axial, Box | Box | ARCOL, HS | Active | 47 Ohms | ±5% | 200W | Wirewound | ±100ppm/°C | - | Non-Inductive, Pulse Withstanding | Aluminum | Flanges | 3.531 L x 2.854 W (89.70mm x 72.50mm) | 1.646 (41.80mm) | Solder Lugs | |
NHS200 1R47 FALUM HOUSE 200W 1.47 OHMS 1% |
2,296 | - |
|
Datasheet |
Axial, Box | Box | ARCOL, HS | Active | 1.47 Ohms | ±1% | 200W | Wirewound | ±100ppm/°C | - | Non-Inductive, Pulse Withstanding | Aluminum | Flanges | 3.531 L x 2.854 W (89.70mm x 72.50mm) | 1.646 (41.80mm) | Solder Lugs | |
NHS200 1R FALUM HOUSE 200W 1 OHMS 1% |
2,476 | - |
|
Datasheet |
Axial, Box | Box | ARCOL, HS | Active | 1 Ohms | ±1% | 200W | Wirewound | ±100ppm/°C | - | Non-Inductive, Pulse Withstanding | Aluminum | Flanges | 3.531 L x 2.854 W (89.70mm x 72.50mm) | 1.646 (41.80mm) | Solder Lugs | |
NHS200 50R FALUM HOUSE 200W 50 OHMS 1% |
3,490 | - |
|
Datasheet |
Axial, Box | Box | ARCOL, HS | Active | 50 Ohms | ±1% | 200W | Wirewound | ±100ppm/°C | - | Non-Inductive, Pulse Withstanding | Aluminum | Flanges | 3.531 L x 2.854 W (89.70mm x 72.50mm) | 1.646 (41.80mm) | Solder Lugs | |
NHS200 16R JALUM HOUSE 200W 16 OHMS 5% |
2,021 | - |
|
Datasheet |
Axial, Box | Box | ARCOL, HS | Active | 16 Ohms | ±5% | 200W | Wirewound | ±100ppm/°C | - | Non-Inductive, Pulse Withstanding | Aluminum | Flanges | 3.531 L x 2.854 W (89.70mm x 72.50mm) | 1.646 (41.80mm) | Solder Lugs | |
HS200 100R FRES CHAS MNT 100 OHM 1% 200W |
3,641 | - |
|
Datasheet |
Axial, Box | Bulk | ARCOL, HS | Active | 100 Ohms | ±1% | 200W | Wirewound | ±100ppm/°C | - | - | Aluminum | Flanges | 3.531 L x 1.791 W (89.70mm x 45.50mm) | 1.646 (41.80mm) | M6 Threaded | |
HS200 2R FRES CHAS MNT 2 OHM 1% 200W |
3,724 | - |
|
Datasheet |
Axial, Box | Bulk | ARCOL, HS | Active | 2 Ohms | ±1% | 200W | Wirewound | ±100ppm/°C | - | - | Aluminum | Flanges | 3.531 L x 1.791 W (89.70mm x 45.50mm) | 1.646 (41.80mm) | M6 Threaded |